Ledger
Every action the operator took or proposed, newest first: the incident, the call it made, its tier, who decided, and what is at stake in customers. Open a row for the evidence, the definition version it ran on, and the undo.
every kind1,020
crew to restored area8estimated bill57housekeeping148outage cluster500planned work collision20priority customer in outage113reverse flow unregistered32transformer overload53voltage out of band10wrong feeder meter39zero consumption40
Showing 10 rows. Housekeeping rows are tickets the operator closed itself once their meters sent a restore.
| # | time | incident | subject | call | tier | status | at stake |
|---|---|---|---|---|---|---|---|
| 721 | Sat 21:00 | transformer overload | transformer 731 | POST /scada/load-transfers transformer=731 target=299 kVA | T2 | asked a person | 40 customers on a transformer at 165.6% of its rating |
| 720 | Sat 21:00 | transformer overload | transformer 1301 | POST /scada/load-transfers transformer=1301 target=299 kVA | T2 | asked a person | 103 customers on a transformer at 152.4% of its rating |
| 719 | Sat 21:00 | transformer overload | transformer 1204 | POST /scada/load-transfers transformer=1204 target=475 kVA | T2 | asked a person | 95 customers on a transformer at 154.2% of its rating |
| 504 | Sat 19:00 | transformer overload | transformer 807 | POST /scada/load-transfers transformer=807 target=475 kVA | T2 | asked a person | 114 customers on a transformer at 168.8% of its rating |
| 503 | Sat 19:00 | transformer overload | transformer 21 | POST /scada/load-transfers transformer=21 target=299 kVA | T2 | asked a person | 66 customers on a transformer at 169.2% of its rating |
| 502 | Sat 19:00 | transformer overload | transformer 1783 | POST /scada/load-transfers transformer=1783 target=299 kVA | T2 | asked a person | 78 customers on a transformer at 151.4% of its rating |
| 241 | Thu 21:00 | transformer overload | transformer 1204 | POST /scada/load-transfers transformer=1204 target=475 kVA | T2 | asked a person | 95 customers on a transformer at 156.5% of its rating |
| 232 | Thu 19:00 | transformer overload | transformer 1083 | POST /scada/load-transfers transformer=1083 target=299 kVA | T2 | asked a person | 57 customers on a transformer at 150.8% of its rating |
| 200 | Wed 20:00 | transformer overload | transformer 2727 | POST /scada/load-transfers transformer=2727 target=475 kVA | T2 | asked a person | 88 customers on a transformer at 152.8% of its rating |
| 157 | Tue 19:00 | transformer overload | transformer 2211 | POST /scada/load-transfers transformer=2211 target=299 kVA | T2 | asked a person | 107 customers on a transformer at 155.6% of its rating |