Feeder Vellmoor Distribution · control room Synthetic data Sun 02:00

Ledger

Every action the operator took or proposed, newest first: the incident, the call it made, its tier, who decided, and what is at stake in customers. Open a row for the evidence, the definition version it ran on, and the undo.

every kind1,020 crew to restored area8estimated bill57housekeeping148outage cluster500planned work collision20priority customer in outage113reverse flow unregistered32transformer overload53voltage out of band10wrong feeder meter39zero consumption40
every status approved38done916declined18asked a person38failed9undone1

Showing 53 rows. Housekeeping rows are tickets the operator closed itself once their meters sent a restore.

#timeincidentsubjectcalltierstatusat stake
1003Sun 01:00transformer overload transformer 2878POST /wfm/work-orders feeder=900 transformer=2878 purpose=thermal_inspection T1failed113 customers on a transformer at 145.5% of its rating
922Sat 23:00transformer overload transformer 561POST /wfm/work-orders feeder=172 transformer=561 purpose=thermal_inspection T3declined102 customers on a transformer at 133.9% of its rating
921Sat 23:00transformer overload transformer 2878POST /wfm/work-orders feeder=900 transformer=2878 purpose=thermal_inspection T3declined113 customers on a transformer at 145.5% of its rating
920Sat 23:00transformer overload transformer 1486POST /wfm/work-orders feeder=462 transformer=1486 purpose=thermal_inspection T3declined122 customers on a transformer at 140.0% of its rating
837Sat 22:00transformer overload transformer 561POST /wfm/work-orders feeder=172 transformer=561 purpose=thermal_inspection T1failed102 customers on a transformer at 133.9% of its rating
836Sat 22:00transformer overload transformer 2878POST /wfm/work-orders feeder=900 transformer=2878 purpose=thermal_inspection T1failed113 customers on a transformer at 145.5% of its rating
835Sat 22:00transformer overload transformer 1486POST /wfm/work-orders feeder=462 transformer=1486 purpose=thermal_inspection T1failed122 customers on a transformer at 140.0% of its rating
834Sat 22:00transformer overload transformer 665POST /wfm/work-orders feeder=208 transformer=665 purpose=thermal_inspection T3declined105 customers on a transformer at 143.0% of its rating
833Sat 22:00transformer overload transformer 59POST /wfm/work-orders feeder=20 transformer=59 purpose=thermal_inspection T3declined97 customers on a transformer at 139.5% of its rating
832Sat 22:00transformer overload transformer 551POST /wfm/work-orders feeder=169 transformer=551 purpose=thermal_inspection T3declined91 customers on a transformer at 145.6% of its rating
831Sat 22:00transformer overload transformer 343POST /wfm/work-orders feeder=108 transformer=343 purpose=thermal_inspection T3declined60 customers on a transformer at 131.0% of its rating
749Sat 21:07transformer overload transformer 1204POST /scada/load-transfers transformer=1204 target=475 kVA T2approved95 customers on a transformer at 154.2% of its rating
743Sat 21:06transformer overload transformer 1301POST /scada/load-transfers transformer=1301 target=299 kVA T2approved103 customers on a transformer at 152.4% of its rating
737Sat 21:04transformer overload transformer 731POST /scada/load-transfers transformer=731 target=299 kVA T2approved40 customers on a transformer at 165.6% of its rating
727Sat 21:00transformer overload transformer 665POST /wfm/work-orders feeder=208 transformer=665 purpose=thermal_inspection T1failed105 customers on a transformer at 143.0% of its rating
726Sat 21:00transformer overload transformer 59POST /wfm/work-orders feeder=20 transformer=59 purpose=thermal_inspection T1failed97 customers on a transformer at 139.5% of its rating
725Sat 21:00transformer overload transformer 551POST /wfm/work-orders feeder=169 transformer=551 purpose=thermal_inspection T1failed91 customers on a transformer at 145.6% of its rating
724Sat 21:00transformer overload transformer 343POST /wfm/work-orders feeder=108 transformer=343 purpose=thermal_inspection T1failed60 customers on a transformer at 131.0% of its rating
723Sat 21:00transformer overload transformer 1477POST /wfm/work-orders feeder=459 transformer=1477 purpose=thermal_inspection T1done48 customers on a transformer at 148.8% of its rating
722Sat 21:00transformer overload transformer 140POST /wfm/work-orders feeder=44 transformer=140 purpose=thermal_inspection T3declined56 customers on a transformer at 132.4% of its rating
721Sat 21:00transformer overload transformer 731POST /scada/load-transfers transformer=731 target=299 kVA T2asked a person40 customers on a transformer at 165.6% of its rating
720Sat 21:00transformer overload transformer 1301POST /scada/load-transfers transformer=1301 target=299 kVA T2asked a person103 customers on a transformer at 152.4% of its rating
719Sat 21:00transformer overload transformer 1204POST /scada/load-transfers transformer=1204 target=475 kVA T2asked a person95 customers on a transformer at 154.2% of its rating
625Sat 20:00transformer overload transformer 140POST /wfm/work-orders feeder=44 transformer=140 purpose=thermal_inspection T1failed56 customers on a transformer at 132.4% of its rating
624Sat 20:00transformer overload transformer 1193POST /wfm/work-orders feeder=368 transformer=1193 purpose=thermal_inspection T1done88 customers on a transformer at 147.0% of its rating
518Sat 19:07transformer overload transformer 1783POST /scada/load-transfers transformer=1783 target=299 kVA T2approved78 customers on a transformer at 151.4% of its rating
517Sat 19:06transformer overload transformer 21POST /scada/load-transfers transformer=21 target=299 kVA T2approved66 customers on a transformer at 169.2% of its rating
515Sat 19:05transformer overload transformer 807POST /scada/load-transfers transformer=807 target=475 kVA T2approved114 customers on a transformer at 168.8% of its rating
509Sat 19:00transformer overload transformer 3047POST /wfm/work-orders feeder=949 transformer=3047 purpose=thermal_inspection T1done85 customers on a transformer at 149.2% of its rating
508Sat 19:00transformer overload transformer 2919POST /wfm/work-orders feeder=910 transformer=2919 purpose=thermal_inspection T1done102 customers on a transformer at 143.3% of its rating
507Sat 19:00transformer overload transformer 2685POST /wfm/work-orders feeder=836 transformer=2685 purpose=thermal_inspection T1done77 customers on a transformer at 130.7% of its rating
506Sat 19:00transformer overload transformer 2473POST /wfm/work-orders feeder=770 transformer=2473 purpose=thermal_inspection T1done90 customers on a transformer at 133.3% of its rating
504Sat 19:00transformer overload transformer 807POST /scada/load-transfers transformer=807 target=475 kVA T2asked a person114 customers on a transformer at 168.8% of its rating
503Sat 19:00transformer overload transformer 21POST /scada/load-transfers transformer=21 target=299 kVA T2asked a person66 customers on a transformer at 169.2% of its rating
502Sat 19:00transformer overload transformer 1783POST /scada/load-transfers transformer=1783 target=299 kVA T2asked a person78 customers on a transformer at 151.4% of its rating
282Fri 22:00transformer overload transformer 2201POST /wfm/work-orders feeder=683 transformer=2201 purpose=thermal_inspection T1done105 customers on a transformer at 126.1% of its rating
280Fri 21:00transformer overload transformer 2381POST /wfm/work-orders feeder=741 transformer=2381 purpose=thermal_inspection T1done97 customers on a transformer at 138.3% of its rating
279Fri 21:00transformer overload transformer 1774POST /wfm/work-orders feeder=549 transformer=1774 purpose=thermal_inspection T1done91 customers on a transformer at 149.4% of its rating
277Fri 20:00transformer overload transformer 2467POST /wfm/work-orders feeder=767 transformer=2467 purpose=thermal_inspection T1done81 customers on a transformer at 137.9% of its rating
243Thu 21:10transformer overload transformer 1204POST /scada/load-transfers transformer=1204 target=475 kVA T2approved95 customers on a transformer at 156.5% of its rating
241Thu 21:00transformer overload transformer 1204POST /scada/load-transfers transformer=1204 target=475 kVA T2asked a person95 customers on a transformer at 156.5% of its rating
235Thu 19:10transformer overload transformer 1083POST /scada/load-transfers transformer=1083 target=299 kVA T2approved57 customers on a transformer at 150.8% of its rating
232Thu 19:00transformer overload transformer 1083POST /scada/load-transfers transformer=1083 target=299 kVA T2asked a person57 customers on a transformer at 150.8% of its rating
201Wed 20:05transformer overload transformer 2727POST /scada/load-transfers transformer=2727 target=475 kVA T2approved88 customers on a transformer at 152.8% of its rating
200Wed 20:00transformer overload transformer 2727POST /scada/load-transfers transformer=2727 target=475 kVA T2asked a person88 customers on a transformer at 152.8% of its rating
199Wed 19:00transformer overload transformer 1083POST /wfm/work-orders feeder=335 transformer=1083 purpose=thermal_inspection T1done57 customers on a transformer at 145.8% of its rating
161Tue 20:00transformer overload transformer 277POST /wfm/work-orders feeder=88 transformer=277 purpose=thermal_inspection T1done79 customers on a transformer at 132.0% of its rating
160Tue 20:00transformer overload transformer 2538POST /wfm/work-orders feeder=791 transformer=2538 purpose=thermal_inspection T1done41 customers on a transformer at 131.2% of its rating
159Tue 19:10transformer overload transformer 2211POST /scada/load-transfers transformer=2211 target=299 kVA T2approved107 customers on a transformer at 155.6% of its rating
158Tue 19:00transformer overload transformer 2675POST /wfm/work-orders feeder=833 transformer=2675 purpose=thermal_inspection T1done64 customers on a transformer at 139.8% of its rating
157Tue 19:00transformer overload transformer 2211POST /scada/load-transfers transformer=2211 target=299 kVA T2asked a person107 customers on a transformer at 155.6% of its rating
121Mon 21:00transformer overload transformer 162POST /wfm/work-orders feeder=51 transformer=162 purpose=thermal_inspection T1done42 customers on a transformer at 145.2% of its rating
86Sun 19:00transformer overload transformer 2289POST /wfm/work-orders feeder=713 transformer=2289 purpose=thermal_inspection T1done86 customers on a transformer at 136.1% of its rating